   power entry modules with line filter 5220 www.schurter.com/pg0 6 emc products iec appliance inlet c14 with filter, fuseholder 1- or 2-pole typ 5220, fuseholder 2-pole snap-in version or screw-on version typ 5220, fuseholder 2-pole snap-in version or screw-on version plug removal necessary for fuse replacement c14 70 c description - panel mount: snap-in or screw-on mounting from front side - 3 functions: appliance inlet protection class i, fuseholder for fuse-links 5 x 20 mm 2-pole, line filter in standard and medical version - quick connect terminals 6.3 x 0.8 mm - alternative: version without line filter 622 0 approvals - vde license number: 101307 - ul license number: e72928 - csa license number: 97784 characteristics - all single elements are already wired - plug removal necessary for fuse-link replacement fuse drawer meets requirements of medical standard iec/en 60601-1 the fuseholder is accessible from the equipment front - qualified for use in equipment according iec/en 60950 references general product informatio n weblinks approval s , roh s , china-roh s , mating connector s , e-stor e , distributor-stock-chec k , accessorie s technical data ratings iec 1 - 10 a @ ta 40 c / 250 vac; 50 hz ratings ul/csa 1 - 10 a @ ta 40 c / 125 vac; 60 hz leakage current standard < 0.5 ma (250 v / 60 hz) medical < 5 a (250 v / 60 hz) dielectric strength > 1.7 kvdc between l-n > 2.7 kvdc between l/n-pe test voltage (2 sec) allowable operation temp. -25 c to 85 c climatic category 25/085/21 acc. to iec 60068-1 degree of protection from front side ip 40 acc. to iec 60529 protection class suitable for appliances with protection class 1 acc. to iec 61140 terminal quick connect terminals 6.3 x 0.8 mm panel thickness s screw: max 8 mm mounting screw torque max 0.5 nm snap-in: 0.8 mm to 3 mm material: housing thermoplastic, black, ul 94v-0 appliance-inlet/-outlet c14 acc. to iec/en 60320-1, ul 498, csa c22.2 no. 42 (for cold conditions) pin-temperature 70 c, 10 a, protection class 1 fuseholder 2-pole, shocksafe category pc2 acc. to iec 60127-6, for fuse-links 5 x 20 mm rated power acceptance @ ta 23 c 5 x 20: 1.6 w (2-pole) power acceptance @ ta > 23c admissible power acceptance at hig - her ambient temperature see derating curves line filter standard and medical version, iec 60939, iec 60601-1, ul 1283, ul 544, en 133 200, csa c22.2 no. 8 technical detail s mtbf > 2'300'000 h acc. to mil-hb-217 f
2 power entry modules with line filter 5220 www.schurter.com/pg0 6 emc products dimensions 57.6 mm screw-on mounting type 5220 ? 6.3x90? 29 34 36 36 44 ? 3.5 m3 +0.50 0 max.r3 32 +0.50 0 43.6 5 2.5 0.2 9 snap-in mounting type 5220 29 34 36 +0.20 0 max.r3 32 +0.20 0 43.8 5 3.5 9 0.2 technical data of filter-components rated current [a] filter-type inductances l [mh] capacitance cx [nf] capacitance cy [nf] r [m ? ] 1 standard version 2 x 11 47 2.2 - 2 standard version 2 x 4 47 2.2 - 4 standard version 2 x 1.6 47 2.2 - 6 standard version 2 x 0.7 47 2.2 - 8 standard version 2 x 0.6 47 2.2 - 10 standard version 2 x 0.4 47 2.2 - 1 medical version (m5) 2 x 11 47 - 1 2 medical version (m5) 2 x 4 47 - 1 4 medical version (m5) 2 x 1.6 47 - 1 6 medical version (m5) 2 x 0.7 47 - 1 8 medical version (m5) 2 x 0.6 47 - 1 10 medical version (m5) 2 x 0.4 47 - 1
 power entry modules with line filter 5220 www.schurter.com/pg0 6 emc products diagrams 5220 standard version 1) line 2) load 5220 medical version 1) line 2) load derating curves 2-pole admissible power ac - ceptance in watt per pole 0 2 0 4 0 6 0 8 0 100 0.2 0.0 i = < < i n i = 0.7 i n i = 1.0 i n 1.6 0.6 0.4 0.8 1.2 1.0 1.4 ambient air temperature ta c attenuation loss - - - - differential mode _____ common mode standard version 1 a 2 a 4 a 6 a 8 a 10 a medical version (m5) 1 a 2 a 4 a 6 a 8 a 10 a technical data of filter-components rated current [a] filter-type inductances l [mh] capacitance cx [nf] capacitance cy [nf] r [m ? ] 1 standard version 2 x 11 47 2.2 - 2 standard version 2 x 4 47 2.2 - 4 standard version 2 x 1.6 47 2.2 - 6 standard version 2 x 0.7 47 2.2 - 8 standard version 2 x 0.6 47 2.2 - 10 standard version 2 x 0.4 47 2.2 - 1 medical version (m5) 2 x 11 47 - 1 2 medical version (m5) 2 x 4 47 - 1 4 medical version (m5) 2 x 1.6 47 - 1 6 medical version (m5) 2 x 0.7 47 - 1 8 medical version (m5) 2 x 0.6 47 - 1 10 medical version (m5) 2 x 0.4 47 - 1
 power entry modules with line filter 5220 www.schurter.com/pg0 6 emc products variants socket and fuse-carrier included rated current [a] filter-type panel mounting fuseholder order number 1 standard version screw 2-pole 5220.0123.1 2 standard version screw 2-pole 5220.0223.1 4 standard version screw 2-pole 5220.0423.1 6 standard version screw 2-pole 5220.0623.1 8 standard version screw 2-pole 5220.0823.1 10 standard version screw 2-pole 5220.1023.1 1 standard version snap-in 2-pole 5220.0143.1 2 standard version snap-in 2-pole 5220.0243.1 4 standard version snap-in 2-pole 5220.0443.1 6 standard version snap-in 2-pole 5220.0643.1 8 standard version snap-in 2-pole 5220.0843.1 10 standard version snap-in 2-pole 5220.1043.1 1 medical version (m5) screw 2-pole 5220.0123.3 2 medical version (m5) screw 2-pole 5220.0223.3 4 medical version (m5) screw 2-pole 5220.0423.3 6 medical version (m5) screw 2-pole 5220.0623.3 8 medical version (m5) screw 2-pole 5220.0823.3 10 medical version (m5) screw 2-pole 5220.1023.3 1 medical version (m5) snap-in 2-pole 5220.0143.3 2 medical version (m5) snap-in 2-pole 5220.0243.3 4 medical version (m5) snap-in 2-pole 5220.0443.3 6 medical version (m5) snap-in 2-pole 5220.0643.3 8 medical version (m5) snap-in 2-pole 5220.0843.3 10 medical version (m5) snap-in 2-pole 5220.1043.3 packaging unit 10 pcs accessorie s description assorted cover s rear cover 0859.0075 cord retaining kit s cord retaining strain relief countersunk, b 4700.0002
5 power entry modules with line filter 5220 www.schurter.com/pg0 6 emc products mating outlets/connector s category / description appliance outlet overview complet e iec appliance outlet f, screw-on mounting, front side, solder or quick-connect terminal 478 7 iec appliance outlet f, snap-in mounting, front side, solder or quick-connect terminal 478 8 iec appliance outlet f or h, screw-on mounting, front side, solder, pcb or quick-connect terminal 509 1 iec appliance outlet f or h, screw-on mounting, front side, solder or quick-connect terminal 509 2 appliance outlet further types to 522 0 connector overview complet e iec connector c15, rewireable, straight 010 1 iec connector c15a, rewireable, straight 010 2 iec connector c15a, rewireable, straight 0102- g iec connector c15a, rewireable, angled 011 2 iec connector c13, rewireable, angled 401 2 connector further types to 522 0 ... power cord overview complet e power cord with iec connector c13, angled 031 1 power cord with iec connector c13, angled 301 1 power cord with iec connector c13, angled 301 2 power cord with iec connector c13, angled 301 3 power cord with iec connector c13 302 0 power cord further types to 522 0 ... the specifications, descriptions and illustrations indicated in this document are based on current information. all content is subject to modifications and amendments.


▲Up To Search▲   

 
Price & Availability of 522006233

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X